Last updated:
Pipeline oxygen limits are set by each transporter's tariff and interconnect agreement. Limits are not universal. Confirm the limit that applies at the receipt point before choosing a range.
Public examples differ. Natural Gas Pipeline Company of America notice 45760 states that Natural's tariff oxygen limit is 10 ppm at the EPNG Moore receipt, and that the EPNG tariff oxygen limit is 2,000 ppm. A Southern Star filing in FERC Docket RP18-276 states a general limit of 0.2 percent by volume of oxygen, and a limit of 10 ppm on line segments 315, 340, and 385. Those documents are examples. Confirm the limit in the tariff or agreement for the receipt point.
Select a measuring range so the limit sits well inside the scale, with headroom above the limit so an upset is visible instead of a pegged signal. Also compare the published detection limit to the tariff number.
For OxyScout, a tariff limit near 10 ppm should use Ultra-Trace (OxyScout-UT, 0–50 ppm). Trace (OxyScout-T, 0–1,000 ppm, detection 50 ppm O2*) is not the right match for a 10 ppm limit because the published detection limit is 50 ppm. Gathering and higher process levels often fit Trace. Percent (OxyScout-P) fits high-level and air-range service, including many blanketing and flare-header checks.
*Based on controlled lab conditions.
The rows below repeat limits stated in the two documents linked at the end of this section. Each row is a reading of that document. The rows are not a new tariff and not a field measurement. Ten ppm by volume is 0.001 percent by volume. Two thousand ppm is 0.2 percent. One percent by volume is 10,000 ppm.
| Document example | Stated oxygen limit | OxyScout range to consider |
|---|---|---|
| NGPL notice 45760, Natural's tariff at that receipt | 10 ppm | Ultra-Trace, 0–50 ppm, detection TBD |
| NGPL notice 45760, EPNG tariff | 2,000 ppm (0.2 percent) | Percent, 0–1 %vol* |
| Southern Star general limit in the 2018 filing | 0.2 percent by volume | Percent, 0–1 %vol* |
| Southern Star line segments 315, 340, and 385 | 10 ppm | Ultra-Trace, 0–50 ppm, detection TBD |
*Based on controlled lab conditions. The Percent 0–1 %vol row follows the band already used for limits from 0.1 percent to 0.4 percent on the pipeline limits page. Trace detection is 50 ppm, so the 10 ppm rows require Ultra-Trace.
Limits are not universal. Pipeline oxygen limits are set by each transporter's tariff and interconnect agreement. Confirm the limit that applies at the receipt point.
Ultra-Trace (OxyScout-UT, 0–50 ppm). Trace detection is 50 ppm, so a 10 ppm limit is not the match for Trace.
Ten ppm by volume is 0.001 percent by volume. One percent by volume is 10,000 ppm.
Book a 30-minute meeting to review your application and we'll send you a quote after the call.
Get a Quote